INSTALLATION, OPERATION& MAINTENANCEINSTRUCTIONS9013-0001 (3/08)WELL-X-TROL® WELL-X1™INSTALLER: LEAVE THIS MANUAL WITH THE OWNERIMPORTANT GENERAL
108. STARTUP & ADJUSTMENT (con't)5.The factory cut-out (pump off) setting is 60 psig. When the pump reaches 60 psig, the Well-X1™ will shut t
111. To enter the programming mode, press and hold the MODE button until LO appears. This is the cut-in setting. Factory default will be 40
123. To adjust the cut-out, depress MODE once and the display will read HI. Again, press thetor s buttons to raise or lower the s
139. PUMP PROTECTION AND DIAGNOSTICSThe Well-X1™ continually monitors pressure, cycle time and voltage to protect the well pump. The following error c
1410. TROUBLESHOOTINGPROBLEM POSSIBLE CAUSE SOLUTIONAlarm sounds 1. Error encountered 1. See Error Code section for possible causes.No water at fixture
1511. REPLACEMENT PARTSDESCRIPTIONPOSITIONWX1-202 WX1-203 WX1-250 WX1-251 WX1-302Replacement tank: Blue1 144R273 146R825 145R379 145R380 150R92Replace
16AMTROL INC. LIMITED PRODUCT WARRANTYProducts covered: all Products manufactured by AMTROL Inc. (“AMTROL”).This warranty cannot be transferred – it i
1. TABLE OF CONTENTSGENERAL SAFETY INFORMATION ... 2COMPONENTS ...
33. COMPONENTSThe Well-X1™ combines all the standard well tank components in a single, easy to install package. The pressure tank, control and tank fi
44. INSTALLATION AND SIZING CONSIDERATIONSThe Well-X1™ functions like a traditional pressure switch by cycling the pump on and off. The factory pressu
55. INSTALLATION CONSIDERATIONSLOCATIONThe Well-X1™ is designed for indoor and outdoor installations. The NEMA 3R enclosure can be installed in direct
66. PLUMBING1. Plumbing connections are similar to a traditional "tank cross" or "tank tee". Provisions are made for popul
74. Connect the water line from the well pump to the inlet of the Well-X1™.5. Plumb the outgoing supply to the building's water supply s
87. WIRINGLINELINEMOTORMOTORBLACKWHITE/STRIPEBLUEWHITETABTABSCREW1. Shut off the circuit breaker for the well system. Loosen the top screw housing cov
98. STARTUP & ADJUSTMENT1. After plumbing and wiring are complete, close the service valve to allow startup without pressurizing the